Hopper insulation cover

For heat dissipation measures of the hopper!

By wrapping the heat insulation cover, the temperature around the hopper will drop by -10℃ or more! By improving safety during onboard i operation, reducing energy consumption for heating, and reducing heat radiation to the installation environment, temperature rise can be suppressed, so power consumption of air conditioning equipment (cooling) can be indirectly reduced. It also leads to restraint.

Features

  • Improved safety
  • Suppression of heat dissipation on the surface of the hopper
  • Effective use of energy
  • Applicable to various dryers

Features of the heat insulation cover

  • heat-resistant resistance ... Continuous 150 ° C (maximum operating temperature 220 ° C)
  • Safety ... Flame retardant, self-extinguishing
  • Chemical resistance: Strong against gasoline, light oils, and solvents such as ethyl acetate and toluene
  • Passed the Food Sanitation Law

Insulation cover material

  • Surface: glass fiber + silicone coating
  • Insulation material: Flexible foam made from melamine resin and ultra-lightweight foam
  • Thickness: 15mm

Example of the effect of a dehumidifier

conditions

  • Model・・・DMZ80-50
  • Material: PBT
  • Drying conditions: temperature 120°C circulation

result

with heat insulating coverNo insulation cover
Hopper surface temperature (top)45°C58°C
Hopper surface temperature (medium)48°C65°C
Hopper surface temperature (bottom)48°C72°C

Content of effect

  • Hopper circumference temperature is low...safety
  • The upper and lower hopper temperatures are small...Heat dissipation is suppressed.

Matsui target model

code numberMatsui target model
21356HD2-10-J
21357HD2-15-J
21358HD2-25-J
21359HD2-50-J
21360HD2-75-J
21361HD2-100-J
21362HD2-150-J
21363HD2-200-J
21364HD2-250-J
21365HD2-300-J

Matsui Solutions

Eliminate wasted energy

Line up